Ko2

CROSS SECTION

Ko2

LONGITUDINAL SECTION

Ko2
Download-in-pdf-icon Download-reader-icon

COIL – KO2

  • universal convector, which also provides heat with the fan switched off
  • high heat output
  • COIL – KO2 is designed for heating of wet interiors especially where flooding is possible (heating of swimming pools) 

DIMENSIONS

total width
380 mm
construction height
151 mm
length
900 - 2500 mm

USAGE

COIL–KO2 is the universal convector suitable for use especially in wet spaces, where intensive flooding of the trough space occurs – e.g. swimming pools. The convector body is divided into 2 sections with a longitudinal partition. The narrower (empty) section of the trough is used to collect most of the water coming into the convector from the swimming pool area thus protecting the wider section of the convector with the fan and heat exchanger from excessive flooding. Both longitudinal separated sections of the convector are fitted with drain pipes for the removal of the water from the bottom of the trough. The partition wall includes fall-over openings. The wider section of the trough with the fan and the heat exchanger is used for standard heating or partial cooling of the interior. The whole body of the unit is covered with an integral grille. The convector features high heat transfer levels when the fan is switched on but it also tempers the space when the fan is switched off. With 12V operation MINIB convectors are safe for applications in wet interiors as well. The convector cannot be installed to swimming pools with salt or other aggressive water.


TEMPERATURE EQUATION - HEATING

Q = μ QN
(
tW-tA 50
)
m
m = 1,012688 temperature exponent
tW, A mean water temperature, mean air temperature [°C]
QN nominal heat transfer rate for temperatures tW/tA 70/20 °C [W]
μ μ = 1 (select μ according to the diagram for other than flow nominal values)
Q heat transfer rate for other [W]

HEAT TRANSFER RATE - Q [W]

°C
°C
°C
°C
length L = 900 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 1 341 1 251 1 215 1 465 1 366 1 327 1 634 1 524 1 480
80 °C 1 161 1 070 1 034 1 268 1 169 1 129 1 414 1 304 1 260
70 °C 980 890 854 1 070 972 933 1 194 1 084 1 040
50 °C 620 530 495 677 579 540 755 646 602
length L = 1000 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 1 565 1 459 1 417 1 710 1 594 1 548 1 906 1 778 1 726
80 °C 1 354 1 249 1 206 1 479 1 364 1 318 1 649 1 521 1 469
70 °C 1 143 1 038 996 1 249 1 134 1 088 1 392 1 264 1 213
50 °C 723 619 577 790 676 630 881 754 703
length L = 1250 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 2 124 1 981 1 923 2 320 2 164 2 101 2 587 2 413 2 343
80 °C 1 837 1 694 1 637 2 007 1 851 1 788 2 238 2 064 1 994
70 °C 1 551 1 409 1 352 1 695 1 539 1 476 1 890 1 716 1 646
50 °C 982 840 783 1 072 917 855 1 196 1 023 954
length L = 1500 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 2 683 2 502 2 430 2 931 2 733 2 654 3 268 3 047 2 959
80 °C 2 321 2 140 2 068 2 535 2 338 2 259 2 827 2 607 2 519
70 °C 1 960 1 779 1 707 2 141 1 944 1 865 2 387 2 167 2 080
50 °C 1 240 1 061 989 1 354 1 159 1 081 1 510 1 292 1 205
length L = 1750 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 3 242 3 023 2 936 3 541 3 302 3 207 3 949 3 682 3 576
80 °C 2 805 2 586 2 499 3 063 2 825 2 730 3 416 3 150 3 044
70 °C 2 368 2 150 2 063 2 587 2 349 2 254 2 884 2 619 2 513
50 °C 1 498 1 282 1 195 1 637 1 400 1 306 1 825 1 561 1 456
length L = 2000 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 3 801 3 544 3 442 4 152 3 872 3 760 4 630 4 317 4 192
80 °C 3 288 3 032 2 930 3 592 3 312 3 200 4 005 3 693 3 569
70 °C 2 776 2 521 2 419 3 033 2 754 2 642 3 382 3 071 2 946
50 °C 1 757 1 503 1 401 1 919 1 641 1 531 2 140 1 830 1 707
length L = 2500 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 4 919 4 587 4 454 5 373 5 010 4 865 5 991 5 587 5 425
80 °C 4 255 3 924 3 791 4 648 4 286 4 141 5 183 4 780 4 618
70 °C 3 593 3 262 3 130 3 925 3 563 3 419 4 376 3 974 3 813
50 °C 2 273 1 945 1 814 2 483 2 124 1 981 2 769 2 369 2 209

Search

News

Catalogue

New catalogue MINIB 2009/2010
Download our new catalogue for the year 2009/2010!



Video

Video

Assembly instructions
for floor convectors
play video »

Assembly instructions
for standing convectors
play video »


Management of quality

En-small

Since the year 2007 we have got the Certificate of Management of Quality for ISO 9001:2001 for the field of activity – manufacture of heating convectors.


EC Declaration of Conformity

Confirmity

All our listed products meet general requirements according to Statutory Rules no. 190/2002 Sb.