Nk

CROSS SECTION

Nk
Download-in-pdf-icon Download-reader-icon

COIL – NK1

  • wall convector with the fan
  • designed for installation on the wall of the room
  • for heating dry interiors
  • equipped with the thermostatic head.

DIMENSIONS

total width
156 mm
construction height
170 mm
length
900 - 2000 mm

USAGE

Wall convectors are fast responding heating units from a higher heat output series of MINIB convectors with 12V fans. They are also suitable for applications when the window sill is placed 25 to 30 cm above the floor so as not to reach the window area.

Info:
The decorative grille of the convector must not be covered or loaded.


TEMPERATURE EQUATION - HEATING

Q = μ QN
(
tW-tA 50
)
m
m = 1,095246 temperature exponent
tW, A mean water temperature, mean air temperature [°C]
QN nominal heat transfer rate for temperatures tW/tA 70/20 °C [W]
μ μ = 1 (select μ according to the diagram for other than flow nominal values)
Q heat transfer rate for other [W]

HEAT TRANSFER RATE - Q [W]

°C
°C
°C
°C
length L = 900 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 1 355 1 257 1 217 1 450 1 344 1 302 1 888 1 750 1 696
80 °C 1 159 1 061 1 023 1 239 1 135 1 094 1 614 1 479 1 425
70 °C 965 869 831 1 032 930 889 1 344 1 211 1 158
50 °C 588 497 461 629 531 493 819 692 642
length L = 1000 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 1 581 1 466 1 420 1 691 1 568 1 519 2 202 2 042 1 978
80 °C 1 352 1 238 1 193 1 446 1 325 1 276 1 883 1 725 1 662
70 °C 1 126 1 014 970 1 204 1 085 1 037 1 568 1 413 1 351
50 °C 686 580 537 734 620 575 956 807 749
length L = 1250 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 2 146 1 990 1 927 2 296 2 128 2 062 2 989 2 772 2 685
80 °C 1 834 1 680 1 619 1 963 1 798 1 732 2 555 2 341 2 256
70 °C 1 528 1 376 1 316 1 634 1 472 1 408 2 128 1 917 1 833
50 °C 931 787 729 996 841 780 1 297 1 096 1 016
length L = 1500 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 2 710 2 513 2 435 2 900 2 689 2 605 3 776 3 501 3 391
80 °C 2 317 2 123 2 045 2 479 2 271 2 188 3 228 2 957 2 849
70 °C 1 930 1 738 1 662 2 064 1 860 1 779 2 688 2 422 2 316
50 °C 1 176 994 921 1 258 1 063 986 1 639 1 384 1 283
length L = 1750 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 3 275 3 037 2 942 3 504 3 249 3 147 4 562 4 230 4 098
80 °C 2 800 2 565 2 471 2 995 2 744 2 644 3 900 3 573 3 443
70 °C 2 332 2 101 2 009 2 495 2 247 2 149 3 248 2 926 2 798
50 °C 1 421 1 201 1 113 1 521 1 284 1 191 1 980 1 672 1 551
length L = 2000 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 3 840 3 560 3 449 4 108 3 809 3 690 5 349 4 960 4 805
80 °C 3 283 3 007 2 898 3 512 3 217 3 100 4 573 4 189 4 036
70 °C 2 734 2 463 2 355 2 925 2 635 2 520 3 808 3 431 3 281
50 °C 1 666 1 408 1 305 1 783 1 506 1 396 2 321 1 961 1 818

Search

News

Catalogue

New catalogue MINIB 2009/2010
Download our new catalogue for the year 2009/2010!



Video

Video

Assembly instructions
for floor convectors
play video »

Assembly instructions
for standing convectors
play video »


Management of quality

En-small

Since the year 2007 we have got the Certificate of Management of Quality for ISO 9001:2001 for the field of activity – manufacture of heating convectors.


EC Declaration of Conformity

Confirmity

All our listed products meet general requirements according to Statutory Rules no. 190/2002 Sb.