Sk2

CROSS SECTION

Sk2
Download-in-pdf-icon Download-reader-icon

COIL – SK2

  • self-standing convector with the fan
  • for heating dry interiors
  • equipped with the thermostatic head.

DIMENSIONS

total width
156 mm
construction height
400 mm
length
900 - 2000 mm

USAGE

Self-standing MINIB convector with the fan suitable for heating of interiors. The modern product made from aesthetically pleasing aluminium alloy and colour matched to MINIB floor convectors. Available in colour tints – silver, light bronze, dark bronze and white.

Info:
The decorative grille of the convector must not be covered or loaded.


TEMPERATURE EQUATION - HEATING

Q = μ QN
(
tW-tA 50
)
m
m = 1,17097 temperature exponent
tW, A mean water temperature, mean air temperature [°C]
QN nominal heat transfer rate for temperatures tW/tA 70/20 °C [W]
μ μ = 1 (select μ according to the diagram for other than flow nominal values)
Q heat transfer rate for other [W]

HEAT TRANSFER RATE Q [W]

°C
°C
°C
°C
length L = 900 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 2 026 1 869 1 807 2 131 1 966 1 900 2 415 2 227 2 153
70 °C 1 409 1 260 1 202 1 482 1 326 1 264 1 679 1 502 1 432
60 °C 1 114 971 914 1 172 1 021 961 1 328 1 157 1 089
45 °C 693 560 508 729 589 534 826 667 605
length L = 1000 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 2 364 2 181 2 108 2 487 2 294 2 217 2 817 2 598 2 512
70 °C 1 644 1 470 1 402 1 729 1 547 1 474 1 959 1 752 1 670
60 °C 1 300 1 132 1 066 1 367 1 191 1 122 1 549 1 349 1 271
45 °C 808 653 592 850 687 623 963 778 706
length L = 1250 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 3 208 2 959 2 861 3 375 3 113 3 009 3 823 3 526 3 409
70 °C 2 231 1 996 1 902 2 347 2 099 2 001 2 659 2 378 2 267
60 °C 1 764 1 537 1 447 1 855 1 616 1 522 2 102 1 831 1 724
45 °C 1 097 886 804 1 154 932 846 1 307 1 056 958
length L = 1500 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 4 053 3 738 3 613 4 263 3 932 3 801 4 829 4 454 4 306
70 °C 2 818 2 521 2 403 2 964 2 651 2 528 3 358 3 004 2 864
60 °C 2 228 1 941 1 828 2 344 2 042 1 923 2 655 2 313 2 178
45 °C 1 386 1 120 1 015 1 458 1 178 1 068 1 652 1 334 1 210
length L = 1750 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 4 897 4 517 4 366 5 151 4 751 4 592 5 835 5 382 5 203
70 °C 3 406 3 046 2 904 3 582 3 204 3 054 4 058 3 630 3 460
60 °C 2 692 2 346 2 209 2 832 2 467 2 323 3 208 2 795 2 632
45 °C 1 675 1 353 1 227 1 762 1 423 1 291 1 996 1 612 1 462
length L = 2000 mm
Fan speed and mean air temperature tA
1 - min. speed 2 - med. speed 3 - max. speed
Mean water temperature tW 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C 15 °C 20 °C 22 °C
90 °C 5 741 5 296 5 119 6 039 5 570 5 384 6 841 6 310 6 100
70 °C 3 993 3 571 3 404 4 200 3 756 3 581 4 758 4 255 4 057
60 °C 3 157 2 750 2 590 3 320 2 892 2 724 3 761 3 277 3 086
45 °C 1 963 1 586 1 438 2 065 1 668 1 513 2 340 1 890 1 714

Electric input for fans DC

length power input
900 12 VA
1000 12 VA
1250 24 VA
1500 24 VA
1750 24 VA
2000 36 VA

Search

News

Catalogue

New catalogue MINIB 2010/2011
Download our new catalogue for the year 2010/2011!



Video

Video

Assembly instructions
for floor convectors
play video »

Assembly instructions
for standing convectors
play video »


Management of quality

En-small

Since the year 2007 we have got the Certificate of Management of Quality for ISO 9001:2001 for the field of activity – manufacture of heating convectors.


EC Declaration of Conformity

Confirmity

All our listed products meet general requirements according to Statutory Rules no. 190/2002 Sb.