P80

CROSS SECTION

P80

LONGITUDINAL SECTION

P80
Download-in-pdf-icon Download-reader-icon

COIL – P80

  • for heating dry interiors
  • lower heat output
  • lower and dimensionally more acceptable variant of the convector COIL-P

DIMENSIONS

total width
243 mm
construction height
80 mm
length
900 - 3000 mm

USAGE

It is recommended for individual use in dry interiors with lower heat demands on intensity of heating and low construction height.


TEMPERATURE EQUATION - HEATING

Q = μ QN
(
tW-tA 50
)
m
m = 1,4062 temperature exponent
tW, A mean water temperature, mean air temperature [°C]
QN nominal heat transfer rate for temperatures tW/tA 70/20 °C [W]
μ μ = 1 (select μ according to the diagram for other than flow nominal values)
Q heat transfer rate for other [W]

HEAT TRANSFER RATE - Q [W]

°C
°C
°C
°C
length L = 900 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 245 221 212
80 °C 199 177 168
70 °C 156 135 127
50 °C 80 64 58
length L = 1000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 286 258 248
80 °C 232 206 196
70 °C 182 158 149
50 °C 94 75 68
length L = 1250 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 388 351 336
80 °C 315 280 266
70 °C 246 214 202
50 °C 127 101 92
length L = 1500 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 490 443 424
80 °C 397 353 336
70 °C 311 271 255
50 °C 161 128 116
length L = 1750 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 592 535 513
80 °C 480 427 406
70 °C 376 327 308
50 °C 194 155 140
length L = 2000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 694 627 601
80 °C 563 501 476
70 °C 441 383 361
50 °C 228 182 164
length L = 2500 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 898 812 778
80 °C 728 648 617
70 °C 570 496 467
50 °C 294 235 212
length L = 3000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 1 102 996 955
80 °C 894 795 757
70 °C 700 609 574
50 °C 361 288 261

Search

News

Catalogue

New catalogue MINIB 2009/2010
Download our new catalogue for the year 2009/2010!



Video

Video

Assembly instructions
for floor convectors
play video »

Assembly instructions
for standing convectors
play video »


Management of quality

En-small

Since the year 2007 we have got the Certificate of Management of Quality for ISO 9001:2001 for the field of activity – manufacture of heating convectors.


EC Declaration of Conformity

Confirmity