COIL – PO/4

  • for heating wet interiors
  • identical in dimension to convectors PO but it has the 4 – tube heat exchanger and therefore a higher output Q

DIMENSIONS

total width
303 mm
construction height
125 mm
length
900 - 3000 mm

USAGE

COIL PO/4 is recommended for individual use in interiors where COIL PO does not efficiently cover the heat requirement. COIL PO/4 has a profiled drain pan to provide drainage of stored water from the trough drain pan. COIL PO/4 can be combined with COIL – KO or COIL – MO, which have a significantly higher heat output. These convectors are equipped with an 18 mm CU drain tube placed in the front of the convector. The convector cannot be installed to swimming pools with salt or other aggressive water.


TEMPERATURE EQUATION - HEATING

Q = μ QN
(
tW-tA 50
)
m
m = 1,466748 temperature exponent
tW, A mean water temperature, mean air temperature [°C]
QN nominal heat transfer rate for temperatures tW/tA 70/20 °C [W]
μ μ = 1 (select μ according to the diagram for other than flow nominal values)
Q heat transfer rate for other [W]

HEAT TRANSFER RATE - Q [W]

°C
°C
°C
°C
length L = 900 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 514 464 445
80 °C 416 370 352
70 °C 326 283 267
50 °C 168 134 121
length L = 1000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 599 542 519
80 °C 486 432 411
70 °C 380 331 311
50 °C 196 156 141
length L = 1250 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 813 735 704
80 °C 659 586 558
70 °C 516 449 423
50 °C 266 212 192
length L = 1500 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 1 027 929 890
80 °C 833 741 705
70 °C 652 567 534
50 °C 336 268 242
length L = 1750 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 1 241 1 122 1 075
80 °C 1 006 895 852
70 °C 788 685 645
50 °C 406 324 293
length L = 2000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 1 455 1 315 1 261
80 °C 1 180 1 049 998
70 °C 924 803 756
50 °C 476 380 343
length L = 2500 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 1 884 1 702 1 631
80 °C 1 527 1 358 1 292
70 °C 1 195 1 039 979
50 °C 616 491 444
length L = 3000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 2 312 2 089 2 002
80 °C 1 874 1 666 1 586
70 °C 1 467 1 275 1 201
50 °C 756 603 545

Search

News

Catalogue

New catalogue MINIB 2009/2010
Download our new catalogue for the year 2009/2010!



Video

Video

Assembly instructions
for floor convectors
play video »

Assembly instructions
for standing convectors
play video »


Management of quality

En-small

Since the year 2007 we have got the Certificate of Management of Quality for ISO 9001:2001 for the field of activity – manufacture of heating convectors.


EC Declaration of Conformity

Confirmity

All our listed products meet general requirements according to Statutory Rules no. 190/2002 Sb.