Pt180

CROSS SECTION

Pt180

LONGITUDINAL SECTION

Pt180
Download-in-pdf-icon Download-reader-icon

COIL – PT180

  • for heating dry interiors
  • high heat output without fan 

DIMENSIONS

total width
303 mm
construction height
180 mm
length
900 - 3000 mm

USAGE

It is recommended for individual use in dry interiors with medium heat demand where the construction height is not a limiting factor.


TEMPERATURE EQUATION - HEATING

Q = μ QN
(
tW-tA 50
)
m
m = 1,43119 temperature exponent
tW, A mean water temperature, mean air temperature [°C]
QN nominal heat transfer rate for temperatures tW/tA 70/20 °C [W]
μ μ = 1 (select μ according to the diagram for other than flow nominal values)
Q heat transfer rate for other [W]

HEAT TRANSFER RATE - Q [W]

°C
°C
°C
°C
length L = 900 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 564 511 490
80 °C 459 410 390
70 °C 362 315 298
50 °C 189 152 138
length L = 1000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 658 596 571
80 °C 536 478 455
70 °C 422 368 347
50 °C 221 177 161
length L = 1250 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 892 808 776
80 °C 727 648 618
70 °C 572 499 471
50 °C 300 240 218
length L = 1500 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 1 127 1 021 980
80 °C 918 819 780
70 °C 723 631 595
50 °C 379 304 275
length L = 1750 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 1 362 1 234 1 184
80 °C 1 110 990 943
70 °C 874 762 719
50 °C 458 367 332
length L = 2000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 1 597 1 447 1 388
80 °C 1 301 1 160 1 105
70 °C 1 024 894 843
50 °C 536 430 390
length L = 2500 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 2 067 1 872 1 796
80 °C 1 684 1 502 1 430
70 °C 1 326 1 157 1 091
50 °C 694 557 504
length L = 3000 mm
Mean air temperature tA
Mean water temperature tW 15 °C 20 °C 22 °C
90 °C 2 536 2 298 2 204
80 °C 2 067 1 843 1 756
70 °C 1 627 1 420 1 339
50 °C 852 683 619

Search

News

Catalogue

New catalogue MINIB 2009/2010
Download our new catalogue for the year 2009/2010!



Video

Video

Assembly instructions
for floor convectors
play video »

Assembly instructions
for standing convectors
play video »


Management of quality

En-small

Since the year 2007 we have got the Certificate of Management of Quality for ISO 9001:2001 for the field of activity – manufacture of heating convectors.


EC Declaration of Conformity

Confirmity

All our listed products meet general requirements according to Statutory Rules no. 190/2002 Sb.